For sales advice please call +44 (0) 1759 304 200

Half Mask Respirators

Half_mask_certificate

Harmonised Standard EN140: 1998

Our respirator masks have been providing protection against dust, mist, fumes, vapour and gas to a variety of industries, supplied through our network of professional PPE distribution

All our products, including all filters, have been designed and manufactured to meet the standards of our ISO 9001 Quality System. Products are tested and certified to the relevant European Standards.

Our half mask meets the requirements of EN140:1999 – being made from Medical Grade PVC and TPE. The CK range of masks are compatible with all CK cartridges and other leading brands of which we can advise you.

We are able to own brand all packaging etc for our customers. We are always happy to offer technical and selection advice to our customers.

Available with or withough head harness
Code Description Qty
CK1004CK1004 H (with harness) Twin respirator with side mounted cartridge PVC Blu/Blk available with or withough head harness. 1
CK1003CK1003 H (with harness) Twin respirator with side mounted cartridge TPE Blu/Blk available with or withough head harness. 1

September 2011 – We appologise to our customers for any inconvinience but we are not currently manufacturing the following items. This will only be short term. For any enquiries please contact angela.musson@detectamet.com

Single respirator with front mounted cartidge PVC CK1005 Blu/Blk available with or withough head harness As CK1001 – Medical Grade PVC body. Half mask respirator with twin cartridge mode 1
Single respirator with droop snoot mode (cartridge under chain) CK1006 Blu/Blk As CK1002 – Medical Grade PVC body. Half mask respirator droop snoot mode mounted 1
Twin disposable respirators CK1010/A1P2 Blu/Blk available with or without head harness 28 day Medical grade PVC c/w A1P2 twin cartridge 1

The Half Mask Single Cartridge Range

September 2011 – We apologise to our customers for any inconvenience but we are not currently manufacturing this item. This will only be short term. For any enquiries please contact angela.musson@detectamet.com

single_respiratorA low cost half mask respirator that conforms to the technical requirements of the European Safety Standard for half-mask respirators, EN 140.

This product includes user friendly design features as standard. Sliding head strap, rolled edge face seal, droop snoot cartridge mode or front mounted, choice of colours, split harness, lightweight. The sliding headstrap allows the user to hang the respirator around the neck when not in use avoiding contamination by placing on a dirty surface.

The rolled edge face seal ensures maximum comfort and prevents soreness of the face. The droop snoot mode of the cartridge fixing allows compatibility with other face shields etc, where unimpaired vision is of utmost importance.

The lightweight design reduces fatigue, when worn for longer periods.

A choice of colours are available for personal preference: we can also offer a choice of materials TPR or Medium grade PVC

Currently available in in one size only (second size to be launched in 2011) The mask has been proven to fit extremely well to female faces and is often a mask of choice for industry employing female workers.

Colours available: Red, Blue, Green and Black
Ref: CK 1006/1002/1001/1005colour – single harness
Ref: CK 1006/1002/1001/1005-colour – split head harness

The CK Half Mask Twin Cartridge Range

twin_respiratorHas all the features of the single cartridge respirator but has been specifically designed for the wearer who requires a slightly reduced inhalation breathing resistance e.g Heavy manual work.

Compatible for use with face shields, welding shields etc.

Colours available: Red, Blue, Green and Black
Ref: CK 1004/1003colour – single harness
Ref: CK 1004/1003colour – split head harness

The CK 28 Day Disposable Half Mask Respirator

Disposible_facemaskSeptember 2011 – We apologise to our customers for any inconvenience but we are not currently manufacturing this item. This will only be short term. For any enquiries please contact angela.musson@detectamet.com

Made from medical grade PVC. This respirator is designed to conform to the requirements of the EN405. The standard does not require any maintenance records to be kept and the respirator can be used for a period not exceeding 28 days.

Our user friendly twin filter respirator comes complete with A1P2(s) – organic vapour/dust combination cartridges. All the comfort features found in the CK 1004 respirator are included in this product. Cartridges are not replaceable.

Colours available: Red, Blue and Black.
Ref CK1010/colour

Gases and Vapours are divided into 4 specific groups
1. A – Organic Vapours/Gases
2. B – Inorganic Vapours/Gases
3. E – Acid Gases/Vapours and Sulphar Dioxide
4. K – Ammonia

The standard given is needed to determine the efficiency of groups of cartridges/canisters and are designated

Class 1
Class 2
Class 3

* Note
a) It is the users responsibility to select the correct cartridge/canister for the hazard (coshh regulations)
b) No negative pressure respirator should be used in areas where the oxygen content is less than 17%

Type Protection Against
A Organic gases and vapours with boiling point >65°C
B Inorganic gases and vapours with boiling point >65°C
E Acid gases and vapours with boiling point >65°C
K Ammonia with boiling point >65°C
ABEK Universal Gases and Vapours

For More Information Click Here

IMPORTANT INFORMATION

We are happy to advise our customers about how to find an accredited Respirator Face Fit Training course to give you the skills and knowledge to meet the requirements of HSE282/28 for Competency of Fit Testing Operators.CK European Safety Equipment Ltd has 2 qualified Fit Testers who will be happy to assist you.

Fit Testing Of Respirators – Training required

RPE Fit Testing is required for all tight-fitting facepieces including all filtering facepieces (disposable face masks), half masks and full-face masks. This includes negative pressure full-face masks as well as power-assisted full masks, and both self-contained and air-fed breathing apparatus.

Information Document HSE 282/28, recommends that RPE Fit Testing should only be conducted by a trained competent person.

The COSHH (Control of Substances Hazardous to Health) Regulations include a requirement that the initial selection process for all tight-fitting facepieces should include face-fit testing to ensure the wearer has a correctly fitting device. Face-Fit Testing is also required under the Control of Asbestos at Work Regulations and the Control of Lead at Work Regulations.

To be competent, the fit test operator should have adequate knowledge and have received adequate instruction and training in the following areas:

  • Regulations and Guidance
  • The Purpose and Applicability of Fit Testing
  • Procedures for Selection of Adequate and Suitable RPE
  • Fit Factors and Protection Factors
  • Examination Procedures for RPE, Identification of Maintenance Problems
  • Correct Donning Procedures and Pre-Use Fit Checks
  • Qualitative and Quantitative Face-Fit Testing
  • Sampling from the Facepiece
  • Diagnostic Checks on Equipment
  • Correct Fit Testing Procedures, Purpose of the Fit Testing Exercises
  • Problem Solving
  • Capabilities and Limitations of the Fit Testing Equipment
  • Interpretation of Results

Visit our online store

Online Store